Module addressable module 2 inputs + 1 output - 4 operating criteria: - alarm, silence, reset or and none - 2 connection modes input: Alarm/Sighting - 1 output status signaling lamp - Surface or DIN mounting with accessory (TFDIN)
SKU: TF-TFM21
Ekskl. moms
Module addressable module 2 inputs + 1 output - 4 operating criteria: - alarm, silence, reset or and none - 2 connection modes input: Alarm/Sighting - 1 output status signaling lamp - Surface or DIN mounting with accessory (TFDIN)
Addressable module of 2 supervised inputs and 1 supervised output, individually identified by the System, occupies maximum 3 addresses.
Programmable function inputs with 4 operating criteria: alarm, silence, reset and none, 2 input connection modes:Alarm or Malfunction.
Output programmable functions with 2 operating criteria: muteable and unmuteable, 2 output type modes: contact or controlled line, with programmable time and delay of actuation, the actuation can be subject to an algebraic formula.
Protected service input for power supply of external devices.
2 input status repeater outputs and 3 input and output status signaling LEDs.
Complete RSC® device management: programming, remote management and control of all operating parameters.
Surface or DIN mounting (TFDIN accessory).
EN 54-18: 2005/AC: 2007 - EN 54-17: 2005.
Approval certificate 1293-CPR-0419.
- TECNOFIRE
- Addressable module, 2 inputs + 1 supervised output:
- Fire-Speed Protocol
- Line separator (IN / OUT) with double isolator
| Device name | TFM21 |
| Description | Module 2 inputs + 1 output |
| Communication protocol | FIRE-SPEED |
| Address | 2 rotary selectors |
| Busy addresses | 1 address for each entry (máx.3) |
| Frequency of interrogation | 2 levels |
| Communication WITNESS | Signaling that can be excluded |
| Performance criteria | 4 for inputs, 2 for outputs |
| Type of entries | Alarm or malfunction |
| Output type | Contact or controlled line |
| Activation delay | Programmable |
| Activation time | Programmable |
| Output activation | Subject to algebraic formula |
| Power | From loop |
| Nominal voltage | 24VDC |
| Operating voltage | 18V...30VDC |
| Standby absorption | 500μA @ 24V DC in absence of communication |
| Absorption in alarm | 2,3mA @ 24V DC |
| Repeater output | 9,4V DC 6mA (protected) |
| Line separator | Intelligent isolator (no device loss) |
| Relay contacts | Max. 30V DC 1A (resistive load) |
| Power | auxiliary out Range da 18V a 30V DC (max. 500mA) |
| Exercise temperature | -15°C...+70°C |
| Relative humidity | 10%...93% (in absence of condensation) |
| Degree of protection | IP40 |
| Container | ABS V0 |
| Dimensions (L x W x D) | 112 x 78 x 25mm |
| Weight | 165g |
| Standards | EN 54-18: 2005/AC: 2007 - EN 54-17: 2005 |
| Certification number | 1293-CPR-0419 |
| Year of CE marking | 14 |
| Benefit statement number | 010_TFM21 |
| Certification body | EVPU |
- Module addressable module 2 inputs + 1 output