Differential circuit breaker - Nominal current 63A - 4 poles (three-phase installations) - Sensitivity 30mA - Trigger type A - For DIN rail
SKU: EBS2L-63A-4P
Ekskl. moms
Differential circuit breaker - Nominal current 63A - 4 poles (three-phase installations) - Sensitivity 30mA - Trigger type A - For DIN rail
The EBS2L range of earth leakage circuit breakers are designed to quickly detect and cut off leakage current to earth, providing essential protection against electric shock and fire hazards in low voltage electrical installations. These devices comply with the IEC/EN 61008-1, standard, which guarantees safe and reliable operation under international standards.
Among its advantages are versatility and compatibility: available in two current ratings and in 2 or 4 pole versions, making them useful in both single-phase and three-phase circuits. Simple installation on standard DIN rail with connections from above or below and good mechanical and thermal support for typical indoor environmental conditions.
In terms of usage scenarios, they are ideal for residential, commercial and small industrial installations where effective protection against earth leakage currents is required. The different sensitivities make them suitable both for protecting small circuits (kitchens or bathrooms) and for general distribution boards where overall system safety is required.
- Differential circuit breaker
- Nominal current 63A
- 4 poles (three-phase installations)
- Sensitivity 30mA
- Trigger type A
- For residential, commercial and industrial installations
- DIN-rail installation
- IP20
- 8000 mechanical life cycles
- 4000 electrical life operations
- Complies with IEC/EN standard 61008-1
| Range | Differential circuit breaker |
| Mounting | DIN Rail 35mm (EN 60175)) |
| Terminal type | Cable / Pin-type busbar / U-type bus bar |
| Connection | Upper / lower |
| Upper connection section | 35mm AWG 18/1 |
| Lower connection section | 35mm AWG 18/1 |
| Torque | 2.5Nm |
| Recommended conductor cross-section | 16mm2 (Nominal current of 50-63A)) 25mm2 (Nominal current of 63-80A)) |
| Dimensions | 72.0 (W) x 81.7 (H) x 74.0 (D) mm |
ELECTRICAL CHARACTERISTICS | |
| Type of leakage | Electromagnetic |
| Rated input current | 63A |
| Type of shot | A |
| Number of poles | 4P (Three phase) |
| Nominal voltage | 415V |
| Insulation voltage | 500V |
| Nominal frequency | 50/60Hz |
| Rated jump capacity | 6000A |
| Short-circuit protection fuse | 6000A |
| Peak voltage | 6000V |
| Dielectric test voltage at industrial frequency (1 min) | 2.5kV |
| Nominal sensitivity | 30mA |
| Maximum interruptible current | 630A |
| Pollution degree | 2 |
MECHANICAL CHARACTERISTICS | |
| Electrical life | 4000 operations |
| Mechanical life | 8000 cycles |
| Degree of protection | IP20 |
| Operating temperature | -5 - 40ºC |
| Storing temperature | -25 - 70ºC |
- Differential circuit breaker